Skip to main navigation Skip to search Skip to main content

Validity of the intraoperative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach

Translated title of the contribution: Validity of the intraoperative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach
  • Y. K. Lee
  • , J. W. Kim
  • , T. Y. Kim
  • , Y. C. Ha
  • , K. H. Koo

Research output: Contribution to journal › Article › peer-review

Abstract

Background: Intraoperative estimation of stem anteversion in total hip arthroplasty (THA) using postero-lateral approach is made by the surgeon's visual assessment, using the tibia as a guide, with the assumption that tibial axis is vertical to the trans-epicondylar axis. However, the accuracy of the intraoperative estimation has rarely been verified with postoperative CT-scans, with controversies regarding these measurements particularly in case of knee osteoarthritis. Therefore, we performed a prospective study to: (1) determine the accuracy of the intraoperative measurement and (2) investigate factors affecting the discrepancy between the surgeon's estimation and the real stem anteversion. Hypothesis: Intraoperative estimation of stem anteversion correlated with the real stem anteversion on CT scan. Patients and methods: Sixty-seven THAs using cementless straight stems (65 patients) without ipsilateral total knee arthroplasty were prospectively evaluated to compare the intraoperative measurement of stem anteversion with the real stem anteversion on computed tomography (CT) scans. There were 33 men and 34 women with a mean age of 59.7 years (range, 27–84 years) at the time of surgery. Age, tibia plateau angle, native femoral anteversion, femoro-tibial angle, body mass index, operative site, gender, coronal and sagittal tilt of the stem, stem type, ipsilateral knee osteoarthritis, and preoperative diagnosis were analyzed to evaluate the factors affecting the discrepancy between the intraoperative and CT measurements. Results: The intraoperative estimation (mean, 21.5° ± 8.5°; range, 5.0°–39.0°) was greater than the CT measurement (mean, 19.5° ± 8.7°; range, 4.5°–38.5°) by 2.0°. The mean absolute value of discrepancy was 4.5°. The correlation coefficient between intraoperative and CT measurements was 0.837. The femoro-tibial angle was associated with the discrepancy between the two measurements. In the presence of genu varum deformity, the intraoperative measurement underestimated the stem anteversion. Discussion: Although intraoperative estimation of stem anteversion was slightly greater than the real stem anteversion, there was an excellent correlation between the two. The femoro-tibial angle should be considered to optimize the stem anteversion during cementless THA using postero-lateral approach. Level of evidence: III, prospective case control study.

Translated title of the contributionValidity of the intraoperative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach
Original languageEnglish
Pages (from-to)236
Number of pages1
JournalRevue de Chirurgie Orthopedique et Traumatologique
Volume104
Issue number3
DOIs
StatePublished - May 2018

Bibliographical note

Publisher Copyright:
© 2018 Elsevier Masson SAS

Keywords

  • Anteversion
  • Cementless stem
  • Femoro-tibial angle
  • Intraoperative estimation
  • Postero-lateral approach
  • Total hip arthroplasty

Fingerprint

Dive into the research topics of 'Validity of the intraoperative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach'. Together they form a unique fingerprint.

Cite this